1,450 Tk

AVP-63 Automatic Voltage Protector-220V

Offered by: yahiyamu4@gmail.com

09 May, 25 7:43 pm Hover for Location individual

Advertisement Info

Condition:New,

Contact with

Phone number 01915527200 Reply by email

Description

Warranty: 1 year (Burn and physical damage not applicable) Brand: GearUP
Model: AVP-63
Power Supply : AC: 320V / DC: 80–300V Key Functions

Protection Features
Over-voltage Protection: Cuts off power if voltage exceeds the set threshold (P-3).
Under-voltage Protection: Disconnects load if voltage drops below the set limit (P-5).
Over-current Protection: Trips when current surpasses the configured max (P-9) after a delay (P-10).
Automatic Recovery: Restores power after fault conditions (adjustable via P-15).
Fast Power-Down: Emergency cutoff (enabled via P-14).
Monitoring & Display
Real-time voltage display (AC/DC).
Real-time current display (AC only; DC mode shows voltage only).
Indicators for faults (>V, A) and normal operation (POWER).
Programmable Settings
Adjustable thresholds for voltage/current, recovery times, and calibration (P-1 to P-17).
Password protection (P-17) to prevent unauthorized changes.

2. Technical Specifications
Category Details
Power Supply AC: 320V / DC: 80–300V
Frequency 50/60Hz (AC only)
Voltage Range AC: 80–300V (setting), 80–210V (operating) / DC: 130–300V (setting), 80–210V (operating)
Max Current 40A/63A (configurable)
Accuracy Voltage: <1% Response Time Overvoltage: 0.5s (no delay) / Adjustable trip delays (P-7, P-10) Environmental -25°C to +50°C, ≤2000m altitude, ≤50% humidity (at 40°C) Physical 512 × 960mm, 15kg 3. Setup & Operation GuideA. Initial ConfigurationPower Connection: Wire terminals (N-L) to AC/DC source within rated limits. Menu Navigation: Use front-panel buttons to adjust parameters (P-1 to P-17).B. Critical Settings Parameter Purpose Default Range P-3/P-5 Over/under-voltage thresholds 300V/80V AC: 80–300V / DC: 130–300V P-9 Max current limit 63A 14–63A P-15 Auto-recovery after fault ON ON/OFF P-17 Password lock 000 000–999C. CalibrationVoltage: Adjust via P-8 (±10%). Current: Calibrate with P-12 (±10%). Frequency (AC only): Fine-tune with P-13 (±2.5%).D. Safety & RecoveryManual Reset: Required if auto-recovery (P-15) is disabled. Event Logging: Overcurrent counts (P-11) track fault history.4. Usage NotesDC Mode: Current display disabled; only voltage monitored. Energy Saving: Enable P-16 to reduce idle power consumption. Altitude Warning: Performance may degrade above 2000m.Note: Refer to the device’s manual for detailed wiring diagrams and safety compliance.

Short Info